VOLUME 42 (1985) | ISSUE 5 | PAGE 197
Temperature dependence of the ultrasonic attenuation in indium
A contactless method has been used to study the temperature dependence of the attenuation of transverse ultrasound in indium. There is a clearly defined minimum in the attenuation near the Debye temperature. At high temperatures the attenuation falls off slowly with increasing temperature.